12616405-2

Circuit Breakers

CIRCUIT BREAKER

12616405-2

5925-01-176-0149

5925 - Circuit Breakers

U S Army Armament Research &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    0.4752 to 0.4787 inches

  • Body Style

    2a single pole type

  • Body Length

    2.000 inches nominal

  • Body Width

    0.750 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Nonturn Device Radius

    0.656 inches nominal

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct single location and 20.000 maximum at 200 pct

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Frequency In Hertz

    400.0 single location

  • Thread Series Designator

    un

  • Bushing Length

    0.625 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Nonturn Device Length

    0.130 inches nominal

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2100.0 ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.500 inches

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Switch Terminal Type

    quick disconnect, male

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Unpackaged Unit Weight

    3.000 ounces

  • Terminal Type And Quantity

    2 tab w/screw

  • Specification/Standard Data

    19200-12616405 manufacturers specification control

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...