Technical Characteristics

  • Bushing Length

    0.328 inches minimum and 0.390 inches maximum

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Trip Release Characteristic

    time delay single location

  • Body Style

    single pole type

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Thread Pitch Diameters

    +0.444/+0.447 inches

  • Mounting Surface To Terminal End Distance

    1.608 inches maximum

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • ~1

    single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 maximum at 500 pct single location and 0.160 minimum at 500 pct single location and 20.000 maximum at 200 pct single location and 2.000 minimum at 200 pct single location and 0.046 minimum at 1000 pct single location and 0.200 maximum at 1000 pct

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location and 2.0 amperes dc single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.742 inches minimum and 0.804 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location and 2000.0 dc single location

  • Frequency In Hertz

    60.0 single location or 400.0 single location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...