UPG101-9491-2

Circuit Breakers

CIRCUIT BREAKER

UPG101-9491-2

5925-01-176-3154

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    1.937 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 65.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    6 wire hook

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    1.050 amperes dc

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    instantaneouss

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.007 minimum at 200 pct and 0.025 minimum at 200 pct

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 1.700 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Frequency In Hertz

    50.0 or b60.0

  • Unpackaged Unit Weight

    5.400 ounces

  • Thread Series Designator

    unef

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...