203-1-1-63-153-1-1
Circuit Breakers
CIRCUIT BREAKER
203-1-1-63-153-1-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Boss Height
0.320 inches nominal
-
Reset Method
manual
-
End Item Identification
4940-01-052-3773
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Body Height
1.630 inches nominal
-
Body Width
0.700 inches nominal
-
Actuator Function
trip-reset
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct single location and 41.000 maximum at 200 pct single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Pole Quantity
1
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 1000.0 dc single location
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location and 32.0 dc single location
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location and 15.0 amperes dc single location
-
Terminal Type And Quantity
2 tab, solder lug
-
Inclosure Protection Type For Which Designed
general purpose
-
Body Style
single pole type
-
Body Length
1.780 inches nominal
-
Mounting Facility Type And Quantity
2 clip
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 single location
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Frequency In Hertz
60.0 single location
-
Case Material
plastic