5004-622

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

5004-622

5915-01-177-0320

5915 - Filters and Networks

Spectrum Control Inc.

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.575 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Operating Current Rating Per Function In Amps

    1.0 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference 2nd function

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Body Width

    0.850 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Functional Terminal Type And Quantity

    1 tab, solder lug ground 3rd function

  • Unthreaded Mounting Hole Diameter

    0.132 inches nominal

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Temp Range

    -55.0/+85.0 deg celsius

  • Body Length

    1.190 inches maximum

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Maximum Voltage Drop Per Function

    1.2 volts ac 1st radio interference

  • Inclosure Type

    encased

  • Functional Terminal Type And Quantity

    1 tab, solder lug input 1st function

  • Overall Length

    1.980 inches maximum

  • Body Height

    1.550 inches maximum

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Functional Terminal Type And Quantity

    1 tab, solder lug output 2nd function

  • Body Material

    metal

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 2nd radio interference

  • Operating Current Rating Per Function In Amps

    1.0 1st radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...