6752-317-20

Circuit Breakers

CIRCUIT BREAKER

6752-317-20

5925-01-177-1597

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    explosion proof and moisture resistant and corrosion resistant and dustproof and sand resistant and fungus resistant

  • Iii Unpackaged Unit Weight

    0.650 pounds

  • Terminal Type And Quantity

    6 tab w/screw

  • Thread Series Designator

    unc

  • Frequency In Hertz

    400.0 all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 50.000 maximum at 200 pct all locations

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Iii Special Handling Feature

    magnetic

  • Iii Storage Type

    general purpose warehouse

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.410 inches minimum and 1.530 inches maximum

  • Body Height

    2.340 inches minimum and 2.400 inches maximum

  • Body Width

    2.250 inches maximum

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Body Style

    4b multipole-single actuator type

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Iii Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.720 inches minimum and 0.780 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.720 inches minimum and 0.780 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.160 inches minimum and 1.220 inches maximum

  • Case Material

    plastic

  • Body Length

    2.189 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...