5189196-007

Circuit Breakers

CIRCUIT BREAKER

5189196-007

5925-01-177-8668

5925 - Circuit Breakers

Raytheon Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.500 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    2 tab, solder lug and 2 wire hook

  • Center To Center Distance Between Terminals Parallel To Length

    0.843 inches minimum and 0.906 inches maximum

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Body Width

    0.625 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unef

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct single location and 0.700 maximum at 200 pct single location

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Pole Quantity

    1

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire hook

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Mounting Surface To Terminal End Distance

    1.750 inches maximum

  • Unpackaged Unit Weight

    1.800 ounces

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...