Technical Characteristics

  • Body Style

    4a single pole type

  • Body Length

    1.968 inches minimum and

  • Body Length

    2.032 inches maximum

  • Body Width

    0.718 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.780 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.844 inches maximum

  • Iii End Item Identification

    4920-01-121-9954

  • Mounting Surface To Terminal End Distance

    1.843 inches minimum and

  • Mounting Surface To Terminal End Distance

    1.907 inches maximum

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Special Features

    black handle

  • Frequency In Hertz

    50.0 or

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Width

    0.782 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.528 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    1.592 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Frequency In Hertz

    60.0 single location

  • Iii Unpackaged Unit Weight

    2.500 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...