205-111-1REC3-42F-4-103-AMO

Circuit Breakers

CIRCUIT BREAKER

205-111-1REC3-42F-4-103-AMO

5925-01-180-0081

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    3.0 millimeters

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Thread Pitch In Millimeters

    0.50

  • Trip Release Duty Cycle

    continuous all locations

  • Thread Series Designator

    iso s

  • Mounting Surface To Terminal End Distance

    2.755 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Test Data Document

    81541-2002 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Features Provided

    high inrush protection

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 control

  • Case Material

    plastic

  • Body Length

    2.490 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

  • Body Width

    2.250 inches maximum

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    3

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 150 pct all locations and 60.000 maximum at 150 pct all locations

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Boss Height

    0.150 inches nominal

  • Switch Current Rating And Type In Amps

    10.0 ac

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Ultimate Trip Time Per Pole In Seconds

    5.000 minimum all locations and 60.000 maximum all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Facility Type And Quantity

    6 threaded hole

  • ~1

    on certain environmental and performance requi

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...