FA32040

Circuit Breakers

CIRCUIT BREAKER

FA32040

5925-01-181-1585

5925 - Circuit Breakers

Schneider Electric Usa Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Body Width

    4.469 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Body Height

    3.156 inches nominal

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.172 inches nominal

  • Body Length

    6.000 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Boss Height

    0.125 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct all locations and 125.000 maximum at 200 pct all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.125 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...