AA1-B0-24-630-4D1-C

Circuit Breakers

CIRCUIT BREAKER

AA1-B0-24-630-4D1-C

5925-01-181-8984

5925 - Circuit Breakers

Carling Technologies, Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    1.990 inches minimum and

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.550 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.650 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.670 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.630 inches minimum and

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    moisture resistant and

  • Frequency In Hertz

    50.0 or

  • Frequency In Hertz

    60.0 single location

  • Iii Unpackaged Unit Weight

    65.0 grams

  • Thread Series Designator

    unc

  • Body Style

    12a single pole type

  • Body Length

    2.010 inches maximum

  • Body Width

    0.755 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.570 inches maximum

  • Boss Height

    0.120 inches minimum and

  • Boss Height

    0.140 inches maximum

  • Mounting Surface To Terminal End Distance

    1.650 inches maximum

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    salt spray proof

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Inclosure Protection Type For Which Designed

    vibration resistant and

  • Terminal Type And Quantity

    2 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...