2900230
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
2900230
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Temp Rise
25.0 deg celsius
-
Maximum Voltage Drop Per Function
1.15 volts ac 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
7.250 inches nominal
-
Body Width
6.250 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Overall Length
15.750 inches nominal
-
Body Surface Treatment
tin
-
Style Designator
rectangular terminal/terminals on adjacent surfaces
-
Operating Temp Range
-0.0/+60.0 deg celsius
-
Operating Current Rating Per Function In Amps
10.0 3rd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Body Material
metal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 1st radio interference
-
Unpackaged Unit Weight
23.000 pounds
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
End Item Identification
mk72m0 gms
-
Body Length
13.750 inches nominal
-
Input Terminal Identification
ms17346r16c10p
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Overall Height
3.600 inches nominal
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Maximum Voltage Drop Per Function
1.15 volts ac 3rd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
14.750 inches nominal
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
Unthreaded Mounting Hole Diameter
0.164 inches nominal
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Operating Current Rating Per Function In Amps
10.0 1st radio interference
-
Input Terminal Manufacturer Code
96906
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Inclosure Type
hermetically sealed
-
Overall Width
8.250 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
10.0 2nd radio interference
-
Mounting Facility Type And Quantity
16 unthreaded hole
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference