203-22-1-61-502-5-1-6
Circuit Breakers
CIRCUIT BREAKER
203-22-1-61-502-5-1-6
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Tripping Mechanism Type
trip free
-
Body Width
1.540 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.050 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Terminal Type And Quantity
4 tab, solder lug
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Unpackaged Unit Weight
2.600 ounces
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Body Height
1.770 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Mounting Facility Type And Quantity
4 clip
-
Body Style
multipole-single actuator type
-
Boss Height
0.250 inches nominal
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
-
Pole Quantity
2
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal