1006313-001

Circuit Breakers

CIRCUIT BREAKER

1006313-001

5925-01-183-6333

5925 - Circuit Breakers

Raytheon Technical Services Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    75.0 milliamperes ac single location and 75.0 milliamperes dc single location

  • Body Length

    1.765 inches maximum

  • Trip Release Method

    magnetic-hydraulic single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Switch Terminal Type

    pin

  • Frequency In Hertz

    60.0 single location

  • Switch Voltage Rating And Type In Volts

    230.0 ac and 28.0 dc

  • Unpackaged Unit Weight

    2.000 ounces

  • Nominal Thread Size

    0.469 inches

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Bushing Length

    0.319 inches nominal

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    1.341 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Width

    0.635 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.005 minimum at 200 pct single location and 0.020 maximum at 200 pct single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.753 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 2500.0 dc single location

  • Switch Current Rating And Type In Amps

    7.0 ac and 7.0 dc

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...