77C717561P001
Filters and Networks
FILTER,BAND PASS
77C717561P001
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Discrimination At Specified Frequencies Per Function In Decibels
1.2 maximum 2nd band pass and 1.2 maximum 2nd band pass and 60.0 minimum 2nd band pass and 60.0 minimum 2nd band pass
-
Output Impedance Per Function W/Source Across Input
2.0 kilohms 2nd band pass
-
Body Height
4.500 inches nominal
-
Inclosure Type
hermetically sealed
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.500 inches nominal
-
Input Impedance Per Function W/Load
2.0 kilohms 1st band pass
-
Operating Temp Range
+15.0/+45.0 deg celsius
-
Overall Height
5.200 inches nominal
-
Mounting Facility Type And Quantity
4 threaded stud
-
Nominal Thread Size
0.250 inches
-
Input Impedance Per Function W/Load
2.0 kilohms 2nd band pass
-
Specified Frequencies Of Discrimination Per Function
5.035 kilohertz 2nd band pass and 5.205 kilohertz 2nd band pass and 4.675 kilohertz 2nd band pass and 5.565 kilohertz 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
10.75 1st band pass
-
Mounting Facility Screw Thread Series Designator
unc
-
Specified Frequencies Of Discrimination Per Function
5.205 kilohertz 1st band pass and 5.035 kilohertz 1st band pass and 4.675 kilohertz 1st band pass and 5.565 kilohertz 1st band pass
-
Reference Frequency Per Function
5.12 single radio interference two phase to two phase
-
Output Impedance Per Function W/Source Across Input
2.0 kilohms 1st band pass
-
Reference Frequency Per Function
5.12 single radio interference pulses per second
-
Functional Terminal Type And Quantity
4 wire hook ground 3rd function
-
Functional Terminal Type And Quantity
2 wire hook output 2nd function
-
Style Designator
rectangular terminal/terminals on one surface
-
Body Width
2.750 inches nominal
-
Frequency Band Width Per Function
5.035 kilohertz 2nd band pass and 5.205 kilohertz 2nd band pass
-
Functional Terminal Type And Quantity
2 wire hook input 1st function
-
Discrimination At Specified Frequencies Per Function In Decibels
1.2 maximum 1st band pass and 1.2 maximum 1st band pass and 60.0 minimum 1st band pass and 60.0 minimum 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.000 inches nominal
-
Frequency Band Width Per Function
5.035 kilohertz 1st band pass and 5.205 kilohertz 1st band pass
-
Body Length
4.375 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
10.75 2nd band pass
-
Unpackaged Unit Weight
24.000 ounces