GJ3-A3-DUW-100-240-1

Circuit Breakers

CIRCUIT BREAKER

GJ3-A3-DUW-100-240-1

5925-01-187-7405

5925 - Circuit Breakers

Heinemann Electric Canada Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Thread Series Designator

    unf

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    6 threaded stud

  • Body Width

    4.500 inches nominal

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Mounting Surface To Terminal End Distance

    3.594 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Length

    7.125 inches nominal

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Center To Center Distance Between Terminals Parallel To Length

    5.625 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Boss Height

    0.219 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    22.000 minimum at 200 pct all locations and 150.000 maximum at 200 pct all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.828 inches nominal

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...