APL-11-1-50-202-M

Circuit Breakers

CIRCUIT BREAKER

APL-11-1-50-202-M

5925-01-188-1170

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    corrosion resistant and shock resistant and moisture resistant and vibration resistant

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Trip Release Characteristic

    instantaneous all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Body Width

    2.484 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc all locations

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.156 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Body Length

    2.448 inches nominal

  • Ultimate Trip Time Per Pole In Seconds

    0.015 maximum all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc all locations

  • Mounting Surface To Terminal End Distance

    2.453 inches nominal

  • Terminal Type And Quantity

    4 threaded stud

  • External Actuator Linkage Arrangement

    one and two linked

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.032 nominal at 150 pct all locations and 150.000 maximum at 150 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...