Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Mounting Surface To Terminal End Distance

    1.313 inches minimum and 1.381 inches maximum

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.365 inches minimum and 0.385 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    70.0 grams

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    general purpose

  • Precious Material And Location

    contact surfaces and terminals silver

  • Body Length

    1.840 inches maximum

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Body Width

    0.730 inches minimum and 0.770 inches maximum

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...