9012GCR-2

Switches

SWITCH,PRESSURE

9012GCR-2

5930-01-188-4215

5930 - Switches

Schneider Electric Usa Inc.

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Load Current Rating

    1.2 amperes inductive load fourth voltage

  • Contact Load Current Rating

    220.0 milliamperes inductive load fifth voltage

  • Overall Length

    8.180 inches nominal

  • Pressure Switch Type

    differential

  • Operating Temp Rating

    -10.0 deg fahrenheit minimum and 185.0 deg fahrenheit maximum

  • Contact Action Stimulus

    decrease

  • Frequency In Hertz

    60.0 fourth voltage

  • Contact Voltage Rating In Volts

    125.0 dc at sea level fifth voltage

  • Contact Voltage Rating In Volts

    250.0 dc at sea level sixth voltage

  • Nominal Thread Size

    0.250 inches first pressure connection

  • Mounting Facility Pattern

    two position in-line

  • Contact Load Current Rating

    6.0 amperes inductive load first voltage

  • Contact Adjustability

    actuation point adjustable

  • Frequency In Hertz

    50.0 fourth voltage and 50.0 third voltage and 50.0 first voltage and 50.0 second voltage and 60.0 second voltage

  • Mounting Method

    bracket and unthreaded hole

  • Contact Load Current Rating

    1.5 amperes inductive load third voltage

  • Inside Diameter

    0.250 inches nominal first connection

  • Contact Voltage Rating In Volts

    480.0 ac at sea level third voltage

  • Nominal Thread Size

    0.750 inches second pressure connection

  • Contact Voltage Rating In Volts

    240.0 ac at sea level second voltage

  • Overall Width

    7.060 inches nominal

  • Distance Between Mounting Facility Centers

    5.880 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.440 inches nominal

  • Inside Diameter

    0.750 inches nominal second connection

  • Contact Voltage Rating In Volts

    600.0 ac at sea level fourth voltage

  • Contact Load Current Rating

    3.0 amperes inductive load second voltage

  • Contact Voltage Rating In Volts

    120.0 ac at sea level first voltage

  • Thread Series Designator

    npt all pressure connection

  • Terminal Type

    screw

  • Overall Height

    5.380 inches nominal

  • Contact Adjustment Range

    +90.00/+2900.00 actuation point pounds per square inch gage

  • Proof Pressure

    15000.00 pounds per square inch gage

  • Media For Which Designed

    gas or liquid

  • Frequency In Hertz

    60.0 third voltage

  • Frequency In Hertz

    60.0 first voltage

  • Nonpile-Up Contact Arrangement

    1 pole, double throw, one position momentary

  • Pressure Connector Type

    plain, threaded internal all connections

  • Contact Load Current Rating

    1.5 amperes resistive load third voltage and 220.0 milliamperes resistive load fifth voltage and 3.0 amperes resistive load second voltage and 6.0 amperes resistive load first voltage and 1.2 amperes resistive load fourth voltage and 110.0 milliamperes

  • ~1

    resistive load sixth voltage and 110.0 milliamp

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...