4310-034-2

Circuit Breakers

CIRCUIT BREAKER

4310-034-2

5925-01-188-4295

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.245 inches minimum and 0.281 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location and 2.0 amperes dc single location

  • Inclosure Protection Type For Which Designed

    moisture resistant and corrosion resistant and sandtight and explosion proof

  • Terminal Type And Quantity

    2 tab, solder lug

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Body Width

    0.593 inches maximum

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    1.590 inches maximum

  • Fragility Factor

    moderately rugged

  • Nonturn Device Diameter

    0.370 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nonturn Device Location

    at 12 oclock

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 2500.0 dc single location

  • Unpackaged Unit Weight

    0.080 pounds

  • Center To Center Distance Between Terminals Parallel To Length

    0.285 inches minimum and 0.315 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Nonturn Device Radius

    0.360 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...