2TC57-10

Circuit Breakers

CIRCUIT BREAKER

2TC57-10

5925-01-188-4296

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Nonturn Device Diameter

    0.370 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nonturn Device Location

    at 12 oclock

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.590 inches maximum

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Body Width

    0.593 inches maximum

  • Inclosure Protection Type For Which Designed

    corrosion resistant and sandtight and moisture resistant and explosion proof

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Bushing Length

    0.245 inches minimum and 0.281 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Nonturn Device Radius

    0.360 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.285 inches minimum and 0.315 inches maximum

  • Unpackaged Unit Weight

    0.080 pounds

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 2500.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...