17524
Coils and Transformers
TRANSFORMER,POWER
17524
Astronautics Corporation Of America
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Voltage
0.60 ac volts nominal single component 4th secondary
-
Mounting Facility Quantity
1 single group
-
Cubic Measure (Non-Core)
3.8 cubic inches
-
Winding Operating Voltage
0.80 ac volts nominal single component 3rd secondary
-
Unpackaged Unit Weight (Non-Core)
0.250 pounds
-
Winding Operating Current
24.0 milliamperes ac maximum single component single primary
-
Body Length
1.860 inches nominal
-
Terminal Type And Quantity
12 wire lead
-
Winding Power Rating
1.4 watts single component single primary
-
Body Width
1.860 inches nominal
-
Winding Operating Voltage
34.00 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
3.00 ac volts nominal single component 1st secondary
-
Body Height
1.110 inches nominal
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Mounting Method
unthreaded hole single group
-
Maximum Operating Temp
105.0 deg celsius
-
Mounting Hole Diameter
0.150 inches nominal single group
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component