219-3-5701-1
Circuit Breakers
CIRCUIT BREAKER
219-3-5701-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 minimum at 200 pct first location and 0.800 maximum at 200 pct first location
-
Body Length
5.110 inches minimum and 5.140 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac first location
-
Auxiliary Switch Function And Quantity
1 alarm
-
Manual Actuator Type And Quantity
3 toggle
-
Terminal Type And Quantity
4 threaded stud
-
Unpackaged Unit Weight
2.000 pounds
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.011 inches minimum and 1.041 inches maximum
-
Internal Trip Release Configuration
relay trip first location
-
Body Width
3.108 inches maximum
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Boss Height
0.205 inches minimum and 0.265 inches maximum
-
Reset Method
manual
-
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
-
Switch Location And Position Designation
internal at pole three
-
Storage Type
general purpose warehouse
-
Switch Current Rating And Type In Amps
10.0 ac
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Mounting Surface To Terminal End Distance
3.535 inches minimum and 3.565 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.735 inches minimum and 2.765 inches maximum
-
Thread Quantity Per Inch
32
-
Center To Center Distance Between Terminals Parallel To Length
3.535 inches minimum and 3.565 inches maximum
-
Frequency In Hertz
60.0 first location
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Characteristic
time delay first location
-
Switch Contact Arrangement
single pole, double throw
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Mounting Facility Type And Quantity
6 threaded hole
-
Center To Center Distance Between Terminals Parallel To Width
1.011 inches minimum and 1.041 inches maximum
-
Nominal Thread Size
0.138 inches
-
Special Features
pole two and pole three are switch only
-
Main Contact Tripping Mechanism Type
trip free