3MC44-3-0.075

Circuit Breakers

CIRCUIT BREAKER

3MC44-3-0.075

5925-01-192-1451

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Body Length

    2.180 inches maximum

  • Switch Terminal Type

    turret

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Bushing Length

    0.290 inches nominal

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    1.343 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Voltage Rating And Type In Volts

    28.0 ac and 230.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 2500.0 dc single location

  • Terminal Type And Quantity

    2 tab, solder lug

  • Inclosure Protection Type For Which Designed

    general purpose

  • Switch Current Rating And Type In Amps

    7.0 ac and 7.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    178.0 single location

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.145 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    75.0 milliamperes ac single location and 75.0 milliamperes dc single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.730 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...