8769969-002
Circuit Breakers
CIRCUIT BREAKER
8769969-002
L-3 Communications Corporation
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Series Designator
unc
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
-
Reset Method
manual
-
Auxiliary Switch Function And Quantity
2 alarm
-
Body Length
2.180 inches maximum
-
Switch Terminal Type
turret
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
-
Mounting Facility Type And Quantity
2 threaded hole
-
Bushing Length
0.290 inches nominal
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
1.343 inches nominal
-
Circuit Protection Type
overcurrent single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Switch Contact Arrangement
single pole, double throw
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Voltage Rating And Type In Volts
28.0 ac and 230.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 2500.0 dc single location
-
Terminal Type And Quantity
2 tab, solder lug
-
Inclosure Protection Type For Which Designed
general purpose
-
Switch Current Rating And Type In Amps
7.0 ac and 7.0 dc
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
178.0 single location
-
Body Style
single pole type
-
Center To Center Distance Between Terminals Parallel To Length
1.145 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
75.0 milliamperes ac single location and 75.0 milliamperes dc single location
-
Trip Release Method
magnetic-hydraulic single location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
-
Frequency In Hertz
60.0 single location
-
Body Width
0.730 inches maximum
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic