AM2-Z397-1

Circuit Breakers

CIRCUIT BREAKER

AM2-Z397-1

5925-01-192-7253

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Frequency In Hertz

    400.0 first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc second location

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Mounting Surface To Terminal End Distance

    2.850 inches maximum

  • Unpackaged Unit Weight

    6.500 ounces

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Internal Trip Release Configuration

    series trip first location

  • Trip Release Characteristic

    time delay first location

  • Mounting Facility Type And Quantity

    4 clip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct first location

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    general purpose

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Trip Release Characteristic

    instantaneous second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Special Features

    pole 2 circuit protection type is major voltage loss or no voltage

  • Manual Actuator Type And Quantity

    2 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • External Actuator Linkage Arrangement

    one and two linked

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac first location

  • Fragility Factor

    moderately rugged

  • Body Width

    1.480 inches minimum and 1.520 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc second location

  • Internal Trip Release Configuration

    relay trip second location

  • Pole Quantity

    2

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...