SDH128A
Relays and Solenoids
RELAY,ELECTROMAGNETIC
SDH128A
Ibex Aerospace Technologies Inc
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 amperes dc resistive load
-
Terminal Type And Quantity
5 threaded stud all functions
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Storage Type
general purpose warehouse
-
Overall Height
2.560 inches maximum
-
Environmental Protection
hermetic
-
Arc Quenching Method
air
-
Main Contact Load Current Rating At Maximum Rated Voltage
60.0 amperes dc motor load
-
Winding Quantity
1
-
Overall Length
3.000 inches nominal
-
Overall Width
2.110 inches nominal
-
Case Material
metal
-
Features Provided
polarized
-
Nonpile-Up Main Contact Arrangement
1 pole, double throw, double break/double make, permanent jumper, one position momentary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.625 inches nominal single mounting facility
-
Unthreaded Mounting Hole Diameter
0.196 inches nominal single mounting facility
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.260 inches nominal single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
100.0 amperes dc inductive load
-
Purpose For Which Designed
general
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Main Contact Maximum Voltage Rating In Volts
28.0 dc
-
Time Delay
0.025 seconds maximum fixed operate and release time
-
Nominal Operating Current Rating And Type
175.0 milliamperes dc single winding
-
Cubic Measure
16.205 cubic inches
-
Duty Type
continuous