5541996-1
Circuit Breakers
CIRCUIT BREAKER
5541996-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Manual Actuator Type And Quantity
3 toggle
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 11.000 maximum at 200 pct all locations
-
Unpackaged Unit Weight
2.000 pounds
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.515 inches minimum and 3.579 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
3.480 inches minimum and 3.614 inches maximum
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Switch Contact Arrangement
single pole, double throw
-
Mounting Facility Type And Quantity
6 threaded hole
-
Body Width
3.046 inches minimum and 3.110 inches maximum
-
Nominal Thread Size
0.138 inches
-
Body Length
5.768 inches minimum and 5.832 inches maximum
-
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
7500.0 ac all locations
-
Mounting Surface To Terminal End Distance
3.460 inches minimum and 3.580 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.996 inches minimum and 1.036 inches maximum
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Switch Terminal Type
turret
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Thread Quantity Per Inch
32
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.996 inches minimum and 1.056 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Boss Height
0.220 inches nominal