HS4816-15

Circuit Breakers

CIRCUIT BREAKER

HS4816-15

5925-01-193-4292

5925 - Circuit Breakers

Boeing Company The

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Body Width

    0.781 inches maximum

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Length

    1.840 inches nominal

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Fragility Factor

    moderately rugged

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.624 inches nominal

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Mounting Surface To Terminal End Distance

    1.381 inches maximum

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Manual Actuator Type And Quantity

    1 push button

  • Inclosure Protection Type For Which Designed

    fungus proof and vibration resistant and shock resistant

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Body Style

    multipole-multiple actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    0.500 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 40.000 maximum at 200 pct all locations

  • Actuator Position Designation

    at pole two

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1200.0 ac all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    68.0 grams

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Frequency In Hertz

    400.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.