HS4844-7R5

Circuit Breakers

CIRCUIT BREAKER

HS4844-7R5

5925-01-193-4294

5925 - Circuit Breakers

Mcdonnell Douglas Helicopter Co Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Bushing Length

    0.470 inches nominal

  • Body Width

    0.593 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Unpackaged Unit Weight

    25.0 grams

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.500 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Nominal Thread Size

    0.438 inches

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac single location and 2500.0 dc single location

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Body Length

    0.781 inches maximum

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location and 7.5 amperes dc single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...