HS4815-35

Circuit Breakers

CIRCUIT BREAKER

HS4815-35

5925-01-193-4299

5925 - Circuit Breakers

Boeing Company The

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.468 inches

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Nonturn Device Length

    0.047 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    1.100 inches maximum

  • Nonturn Device Radius

    0.375 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.218 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.750 inches maximum

  • Nonturn Device Width

    0.078 inches nominal

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Bushing Length

    0.250 inches nominal

  • Special Handling Feature

    magnetic

  • Inclosure Protection Type For Which Designed

    dustproof

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 15.000 maximum at 200 pct single location

  • Nonturn Device Location

    at 12 oclock

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...