Technical Characteristics
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac third location
-
Thread Series Designator
unef
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 minimum at 200 pct third location and 4.500 maximum at 200 pct third location
-
Internal Trip Release Configuration
relay trip first location
-
Bushing Length
0.380 inches maximum
-
Pole Quantity
3
-
Unpackaged Unit Weight
4.800 ounces
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 minimum at 200 pct second location and 4.500 maximum at 200 pct second location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac first location
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Terminal Type And Quantity
2 tab, solder lug and 6 wire hook
-
Circuit Protection Type
overcurrent second location
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Circuit Protection Type
overcurrent third location
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Actuator Position Designation
at pole two
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Body Style
multipole-single actuator type
-
Trip Release Characteristic
instantaneous first location
-
Case Material
metal
-
Internal Trip Release Configuration
series trip second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Manual Actuator Type And Quantity
1 toggle
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac second location
-
Circuit Protection Type
overvoltage first location
-
Trip Release Characteristic
time delay second location
-
Internal Trip Release Configuration
series trip third location
-
Body Width
1.937 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Trip Release Characteristic
time delay third location
-
Body Length
1.562 inches maximum
-
Frequency In Hertz
50.0 all locations or 60.0 all locations