801854-115

Circuit Breakers

CIRCUIT BREAKER

801854-115

5925-01-197-4689

5925 - Circuit Breakers

Evans & Sutherland Computer

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    1.468 inches minimum and 1.532 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.718 inches minimum and 0.782 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.628 inches minimum and 1.692 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.718 inches minimum and 0.782 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Reset Method

    manual

  • External Actuator Linkage Arrangement

    one and two linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 22.000 maximum at 200 pct

  • Terminal Type And Quantity

    4 quick disconnect, male

  • Body Style

    1c multipole-multiple actuator type

  • Bushing Length

    0.098 inches minimum and 0.162 inches maximum

  • Body Length

    1.968 inches minimum and 2.032 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.528 inches minimum and 1.592 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.898 inches minimum and 1.962 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    25.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    60.0 all locations

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...