722-034-001
Coils and Transformers
TRANSFORMER,POWER
722-034-001
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Tap Location
center tap single component all secondary
-
Winding Function And Quantity
2 primary single component and 2 secondary
-
Mounting Method
slot single group
-
Body Width
3.120 inches nominal
-
Body Length
4.120 inches nominal
-
Mounting Slot Width
0.190 inches nominal single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.500 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Winding Operating Voltage
20.00 dc volts nominal single component 1st secondary
-
Winding Operating Current
1.0 amperes dc minimum single component 1st secondary and 1.5 amperes dc maximum
-
Cubic Measure
48.2 cubic inches
-
Mounting Facility Quantity
4 single group
-
Inclosure Type
fully inclosed
-
Body Height
3.750 inches nominal
-
Input-Output Phase Relationship
single phase to single phase single component
-
Frequency Rating
47.0 hertz minimum single component and 420.0 hertz maximum
-
Terminal Type And Quantity
14 tab, solder lug
-
Special Features
all secondary voltages & currents are shown as rectified; secondary one as a positive and negative 20 volt output
-
Winding Operating Voltage
105.00 ac volts minimum single component all primary and 125.00 ac volts maximum
-
Winding Operating Voltage
10.00 dc volts nominal single component 2nd secondary
-
Winding Operating Current
6.0 amperes dc maximum single component 2nd secondary
-
Winding Tap Location
multiple taps w/o center tap single component all primary