Technical Characteristics
-
Contact Load Current Rating
10.0 amperes inductive load first voltage
-
Special Features
tamper proof external adjustment,contains viton diaphragm
-
Mounting Method
bracket and unthreaded hole
-
Contact Voltage Rating In Volts
480.0 ac at sea level third voltage
-
Overall Width
2.593 inches nominal
-
Contact Adjustment Type
external actuation point screw
-
Thread Series Designator
npt first pressure connection
-
Thread Quantity Per Inch
14 second threaded hole
-
Hazardous Locations/Environmental Protection
explosion proof
-
Contact Load Current Rating
0.5 amperes inductive load fifth voltage
-
Contact Load Current Rating
3.0 amperes inductive load third voltage
-
Pressure Switch Type
gage
-
Contact Load Current Rating
10.0 amperes inductive load second voltage
-
Nominal Thread Size
0.250 inches first pressure connection
-
Thread Series Designator
npt second threaded hole
-
Mounting Facility Pattern
two position in-line
-
Contact Voltage Rating In Volts
6.0 dc at sea level fourth voltage
-
Pressure Connector Type
plain, threaded internal single connection
-
Contact Load Current Rating
0.5 amperes inductive load fourth voltage
-
Inside Diameter
0.250 inches nominal single connection
-
Unthreaded Mounting Hole Diameter
0.281 inches nominal
-
Contact Voltage Rating In Volts
24.0 dc at sea level fifth voltage
-
Overall Height
5.281 inches nominal
-
Contact Voltage Rating In Volts
250.0 ac at sea level second voltage
-
Proof Pressure
2000.00 pounds per square inch gage
-
Terminal Type
screw
-
Style Designator
rectangular
-
Contact Adjustment Range
+1.00/+30.00 actuation point pounds per square inch gage and +0.50/+28.50 deactuation point pounds per square inch gage
-
Media For Which Designed
gas or liquid
-
Thread Quantity Per Inch
18 first pressure connection
-
Contact Adjustability
actuation point adjustable, preset and deactuation point adjustable, preset
-
Contact Voltage Rating In Volts
125.0 ac at sea level first voltage
-
Nominal Thread Size
0.500 inches second threaded hole
-
Contact Stimulus Rating
0.10 differential point minimum pounds per square inch gage and 1.50 differential point maximum pounds per square inch gage