WE 2269
Coils and Transformers
TRANSFORMER,POWER
WE 2269
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Nominal Thread Size
0.164 inches single group
-
Body Height
4.850 inches minimum and 4.910 inches maximum
-
Winding Tap Location (Non-Core)
err-070
-
Test Data Document
03024-8-60014627 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Mounting Method
threaded stud single group
-
Body Length
3.530 inches minimum and 3.590 inches maximum
-
Frequency Rating
57.0 hertz minimum single component and 63.0 hertz maximum single component
-
Winding Operating Voltage
103.50 ac volts nominal single component single primary and 115.00 ac volts nominal single component single primary and 126.50 ac volts nominal single component single primary
-
Maximum Operating Temp
105.0 deg celsius
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Terminal Type And Quantity
14 turret
-
Reliability Indicator
not established
-
Winding Operating Voltage
33.50 ac volts nominal single component 1st secondary
-
Thread Class (Non-Core)
err-070
-
Winding Operating Current
1.1 amperes ac nominal single component all secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Power Rating
36.9 volts-amperes single component 1st secondary
-
Body Width
3.030 inches minimum and 3.090 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.115 inches minimum single mounting facility single center group and 2.135 inches maximum single mounting facility single center group
-
Winding Power Rating
3.6 volts-amperes single component 3rd secondary
-
Inclosure Type
hermetically sealed
-
Winding Power Rating
36.9 volts-amperes single component 2nd secondary
-
Thread Series Designator
unc single group
-
Winding Operating Voltage
33.50 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
3.30 ac volts nominal single component 3rd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.615 inches minimum single mounting facility single center group and 2.635 inches maximum single mounting facility single center group
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Thread Direction (Non-Core)
err-070