JC1-B3-JB-5-3
Circuit Breakers
CIRCUIT BREAKER
JC1-B3-JB-5-3
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Inclosure Protection Type For Which Designed
dustproof
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Mounting Surface To Terminal End Distance
1.898 inches minimum and 1.962 inches maximum
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Body Width
0.718 inches minimum and 0.782 inches maximum
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Body Length
1.968 inches minimum and 2.032 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Center To Center Distance Between Terminals Parallel To Length
1.528 inches minimum and 1.592 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct single location and 1.500 maximum at 200 pct single location
-
Terminal Type And Quantity
2 quick disconnect, male
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.628 inches minimum and 1.692 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Case Material
plastic