15315
Switches
SWITCH,PRESSURE
15315
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 160.0 deg fahrenheit maximum
-
Contact Adjustability
actuation point adjustable and deactuation point adjustable
-
Contact Load Current Rating
2.0 amperes resistive load single voltage
-
Contact Adjustment Range
+2150.00/+2250.00 actuation point pounds per square inch gage and +1900.00/+2100.00 deactuation point pounds per square inch gage
-
Sensing Element Burst Pressure
7500.00 pounds per square inch gage
-
Mounting Method
plug-in terminal
-
Nonpile-Up Contact Arrangement
1 pole, double throw, both positions maintained
-
Overall Length
3.000 inches maximum
-
Thread Series Designator
unf single pressure connection
-
Thread Class
3a single pressure connection
-
Media For Which Designed
gas or liquid
-
Pressure Connector Type
flared, threaded external single connection
-
Contact Adjustment Type
external actuation point hex nut and external deactuation point hex nut
-
Contact Action Stimulus
increase
-
Nominal Thread Size
0.438 inches single pressure connection
-
Proof Pressure
4500.00 pounds per square inch gage
-
Pressure Switch Type
gage
-
Terminal Type
connector, plug
-
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
-
Outside Diameter
0.674 inches nominal single connection
-
Overall Diameter
0.890 inches maximum
-
Style Designator
cylindrical