AM4-Z111-2

Circuit Breakers

CIRCUIT BREAKER

AM4-Z111-2

5925-01-202-9989

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    107.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    4 toggle

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 85.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    moisture resistant and humidity resistant and shock resistant and vibration resistant

  • Special Features

    interrupt current capacity is 5000 amps when a proper back-up breaker and/or fuse is used in the circuit

  • Frequency In Hertz

    50.0 or b60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    10 threaded stud

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Pole Quantity

    4

  • Body Length

    2.499 inches minimum and 2.510 inches maximum

  • Body Width

    2.990 inches minimum and 3.100 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,three,and four linked

  • Internal Trip Release Configuration

    relay trip

  • Nominal Thread Size

    0.138 inches

  • Unpackaged Unit Weight

    12.500 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.