ETN275410

Circuit Breakers

CIRCUIT BREAKER

ETN275410

5925-01-204-6096

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Unpackaged Unit Weight

    5.500 pounds

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Switch Current Rating And Type In Amps

    15.0 ac and 15.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Body Length

    6.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.312 inches nominal

  • Switch Terminal Type

    wire lead

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations and 100.0 amperes dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.938 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Terminal Type And Quantity

    6 compression

  • Boss Height

    0.188 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Inclosure Protection Type For Which Designed

    general purpose

  • Frequency In Hertz

    400.0 all locations

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations and 10000.0 dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.688 inches nominal

  • Switch Voltage Rating And Type In Volts

    460.0 ac and 250.0 dc

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Body Height

    3.875 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...