UPG-6-1-REC3-52-253-9
Circuit Breakers
CIRCUIT BREAKER
UPG-6-1-REC3-52-253-9
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
12a single pole type
-
Body Width
0.735 inches minimum and 0.765 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Special Features
white handle with white markings
-
Iii Unpackaged Unit Weight
2.200 ounces
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Case Material
plastic
-
Iii Fragility Factor
moderately rugged
-
Boss Height
0.115 inches minimum and 0.145 inches maximum
-
Mounting Surface To Terminal End Distance
2.032 inches maximum
-
Iii Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
2 threaded hole
-
Iii Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Switch Location And Position Designation
internal at pole one
-
Switch Terminal Type
screw
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Thread Series Designator
unc
-
Terminal Type And Quantity
2 screw
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.645 inches minimum and 1.675 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Pole Quantity
1
-
Iii Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
magnetic-hydraulic single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Auxiliary Switch Function And Quantity
1 alarm
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct and 10.000 maximum at 200 pct single location
-
Inclosure Protection Type For Which Designed
moisture resistant and salt spray proof and shock resistant and vibration resistant
-
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc