LS10187-1

Circuit Breakers

CIRCUIT BREAKER

LS10187-1

5925-01-205-7480

5925 - Circuit Breakers

Lockheed Martin Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    0.5 amperes ac single location

  • Nominal Thread Size

    0.469 inches

  • Auxiliary Switch Function And Quantity

    1 control

  • Thread Series Designator

    uns

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location

  • Bushing Length

    0.277 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.742 inches minimum and 0.804 inches maximum

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Switch Current Rating And Type In Amps

    0.5 ac

  • Switch Location And Position Designation

    external at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    moisture resistant and explosion resistant and vibration resistant

  • Specification/Standard Data

    36659-ls10187 manufacturers standard

  • Case Material

    metal

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.287 inches minimum and 1.317 inches maximum

  • Manual Actuator Type And Quantity

    1 push-pull

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Circuit Protection Type

    overcurrent single location

  • Switch Voltage Rating And Type In Volts

    115.0 ac

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Ultimate Trip Time Per Pole In Seconds

    2.000 minimum single location and 20.000 maximum single location

  • Terminal Type And Quantity

    2 screw

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Switch Terminal Type

    turret

  • Reset Method

    manual

  • Frequency In Hertz

    2000.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...