LS10158-35P

Circuit Breakers

CIRCUIT BREAKER

LS10158-35P

5925-01-205-7481

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.040 inches minimum and 0.055 inches maximum

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    thermal

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.469 inches

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum

  • Frequency In Hertz

    400.0

  • Specification/Standard Data

    36659-ls10158 manufacturers standard

  • Body Length

    0.730 inches minimum and 0.770 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    0.673 inches minimum and 0.735 inches maximum

  • Mounting Surface To Terminal End Distance

    1.281 inches minimum and 1.343 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct and 20.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    general purpose

  • Special Features

    breaker terminal furnished with lockwasher and phillips head screw

  • Unpackaged Unit Weight

    0.057 pounds

  • Proprietary Characteristics

    pacs

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...