LS10158-15

Circuit Breakers

CIRCUIT BREAKER

LS10158-15

5925-01-205-7482

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    0.730 inches minimum and 0.770 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.675 inches minimum and 0.735 inches maximum

  • Mounting Surface To Terminal End Distance

    1.281 inches minimum and 1.343 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum single location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location

  • Specification/Standard Data

    36659-ls10158 manufacturers standard

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    0.057 pounds

  • Bushing Length

    0.040 inches minimum and 0.055 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...