6766-20-80-I
Circuit Breakers
CIRCUIT BREAKER
6766-20-80-I
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Protection Type For Which Designed
general purpose
-
Body Style
single pole type
-
Overall Length
80.16 millimeters nominal
-
Case Material
plastic
-
Actuator Function
reset
-
Fragility Factor
moderately rugged
-
Maximum Continuous Load Current Rating Per Pole
80.0 amperes dc single location
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
61.11 millimeters nominal
-
Manual Actuator Type And Quantity
1 push button
-
Terminal Type And Quantity
2 screw
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Pole Quantity
1
-
Center To Center Distance Between Terminals Parallel To Length
27.0 millimeters nominal
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
2 threaded stud
-
Body Width
47.6 millimeters nominal
-
Operating Voltage Type And Rating Per Pole In Volts
110.0 dc single location