Technical Characteristics
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Nominal Operating Current Rating And Type
120.0 milliamperes dc single winding
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts teardrop, two holes type 4f single winding
-
Specification/Standard Data
81349-mil-r-6106/13 government specification
-
Storage Type
general purpose warehouse
-
Time Delay
0.015 seconds maximum fixed operate and release time
-
Environmental Protection
hermetic
-
Auxiliary Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Nonpile-Up Auxiliary Contact Arrangement
1 pole, double throw, one position momentary
-
~1
data on certain environmental and performance
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches nominal single mounting facility
-
Duty Type
continuous
-
Main Contact Load Current Rating At Maximum Rated Voltage
12.0 amperes dc inductive load
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac motor load and 5.0 amperes dc motor load
-
Cubic Measure
2.985 cubic inches
-
Overall Height
1.695 inches maximum
-
Coil Quantity
1
-
Overall Width
1.025 inches maximum
-
Purpose For Which Designed
general
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac lamp load and 5.0 amperes dc lamp load
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, momentary action
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac resistive load and 2.0 amperes dc resistive load
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Mounting Facility Pattern
triangle single mounting facility
-
Features Provided
polarized
-
Terminal Type And Quantity
11 wire hook all functions
-
Case Material
metal
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility
-
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes ac resistive load and 25.0 amperes dc resistive load
-
Overall Length
1.718 inches maximum
-
Winding Quantity
1
-
Arc Quenching Method
air