SAE-AS14154-20

Circuit Breakers

CIRCUIT BREAKER

SAE-AS14154-20

5925-01-217-1643

5925 - Circuit Breakers

Society Of Automotive Engineers Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Body Length

    0.781 inches maximum

  • Storage Type

    general purpose warehouse

  • ~1

    data on certain environmental and performance

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Body Width

    1.840 inches maximum

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    71.0 deg fahrenheit nominal all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Specification/Standard Data

    96906-ms14154 government standard

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.593 inches minimum and 0.655 inches maximum

  • Thread Series Designator

    un

  • Body Height

    1.381 inches maximum

  • Terminal Type And Quantity

    6 tab w/screw

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Frequency In Hertz

    400.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...