WC375/07-010

Circuit Breakers

CIRCUIT BREAKER

WC375/07-010

5925-01-221-0677

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    thermal-magnetic all locations

  • Terminal Type And Quantity

    3 clip and 3 compression

  • Body Width

    2.193 inches minimum and 2.241 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches nominal

  • Boss Height

    0.188 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Manual Actuator Type And Quantity

    3 toggle

  • Case Material

    plastic

  • Body Length

    3.025 inches minimum and 3.065 inches maximum

  • Storage Type

    general purpose warehouse

  • ~1

    data on certain environmental and performance re

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Specification/Standard Data

    81348-w-c-375/7 government specification

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 terminal

  • Circuit Protection Type

    overcurrent all locations

  • Body Height

    2.371 inches minimum and 2.433 inches maximum

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...