SCD51990322-001

Circuit Breakers

CIRCUIT BREAKER

SCD51990322-001

5925-01-226-5942

5925 - Circuit Breakers

Harris Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.175 minimum at 200 pct third location and 2.000 maximum at 200 pct third location

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.5 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Internal Trip Release Configuration

    series trip second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Frequency In Hertz

    400.0 third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.175 minimum at 200 pct second location and 2.000 maximum at 200 pct second location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Switch Terminal Type

    quick disconnect, male

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Pole Quantity

    4

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac first location

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Trip Release Characteristic

    time delay second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Internal Trip Release Configuration

    series trip third location

  • Frequency In Hertz

    400.0 second location

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac second location

  • Circuit Protection Type

    overvoltage fourth location

  • Main Contact Tripping Mechanism Type

    trip free

  • Special Features

    pole four trips with volts only

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Characteristic

    time delay third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Trip Release Characteristic

    instantaneous fourth location

  • Inclosure Protection Type For Which Designed

    salt water resistant and moisture resistant and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.175 minimum at 200 pct first location and 2.000 maximum at 200 pct first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac third location

  • Internal Trip Release Configuration

    relay trip fourth location

  • Fragility Factor

    moderately rugged

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc fourth location

  • Terminal Type And Quantity

    10 threaded stud

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Frequency In Hertz

    400.0 first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc fourth location

  • Circuit Protection Type

    overcurrent second location

  • Thread Quantity Per Inch

    32

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.