AM3R-A15A2A3-LC-07-D-A-25-2-V11-
Circuit Breakers
CIRCUIT BREAKER
AM3R-A15A2A3-LC-07-D-A-25-2-V11-
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Arc Quenching Method
magnetic blowout
-
Trip Release Characteristic
time delay third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct third location and 20.000 maximum at 200 pct third location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Switch Terminal Type
quick disconnect, male
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Case Material
plastic
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Body Width
2.240 inches minimum and 2.251 inches maximum
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
115.0 ac nominal first location
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
0.1 ac and 0.1 dc
-
Mounting Facility Type And Quantity
6 threaded hole
-
Supplementary Features
extra long part number 4agl7/am3r-a15a2a3-lc-07-d-a-25-2-v115p
-
Internal Trip Release Configuration
series trip second location
-
Nominal Thread Size
0.138 inches
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Trip Release Characteristic
instantaneous first location and time delay first location
-
Frequency In Hertz
60.0 all locations
-
Trip Release Characteristic
time delay second location
-
Terminal Type And Quantity
7 threaded stud
-
Internal Trip Release Configuration
series trip third location
-
Main Contact Tripping Mechanism Type
trip free
-
Fragility Factor
moderately rugged
-
Internal Trip Release Configuration
series trip w/remote trip feature first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Trip Release Duty Cycle
intermittent first location
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Storage Type
general purpose warehouse
-
Switch Voltage Rating And Type In Volts
125.0 ac and 30.0 dc
-
Switch Location And Position Designation
internal at pole two
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked